Ready For Sale

Whatsapp »
SKU: MB46O1V1XI3

Secondhand GE Logiq 3 Expert Ultrasound Machine

, , , ,

Price: USD$ 3.300,00 Approx: 148.500,00 TL

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      If there is a local operation center in the seller's country:

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      If there is no operation center in the seller's country:

      • Technical Inspection: Inspections are performed by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 10.02.2026

      GE LOGIQ 3 Expert Ultrasound Imaging System Analysis Report

      Device Identification

      The device in the examined visuals is a medical ultrasonography (ultrasound) device mounted on a wheeled stand, with a fixed monitor and a keyboard console. The system consists of a main unit, monitor, control panel, probe ports, integrated data recording units, and interchangeable imaging probes.

      Brand and Model

      As a result of detailed analysis of the visuals, the brand and model of the device have been clearly identified:

      • Main Device Brand: GE (General Electric)
      • Main Device Model: LOGIQ 3 Expert
      • Accessory Device (Sub-Unit): A “Sony” logo is visible on an optical drive or recording unit integrated into the bottom part of the chassis.

      The model information is confirmed by the “LOGIQ 3 Expert” inscription on the top left corner of the monitor frame and the iconic GE logo in the center of the console. The “Expert” inscription indicates that it is a version featuring different software or hardware characteristics compared to the standard LOGIQ 3 model.

      Probe (Transducer) Details

      The details of the two probes displayed with the device can be clearly read from the visuals:

      • Probe 1 Brand-Model: GE 10L. (Type: Linear Probe). Generally used for superficial tissues, vascular structures, thyroid, breast, and musculoskeletal imaging.
      • Probe 2 Brand-Model: GE 3.5C. (Type: Convex Probe). Generally used for abdominal, obstetric, and gynecological imaging. It is understood from the coding that it has a center frequency of 3.5 MHz.

      Originality

      Upon examining the logos on the device, material quality, keypad layout, and the craftsmanship of the probe connection points, the product is assessed to be an original GE medical device. There is no indication of it being a counterfeit or replica.

      Areas of Use

      This device is used for diagnostic purposes in medical imaging centers, hospital radiology departments, obstetrics and gynecology clinics, and emergency rooms. With the current probe set (Linear and Convex), it is suitable for the following applications:

      • Abdominal (Imaging of internal abdominal organs)
      • Obstetric and Gynecological examinations
      • Superficial tissue imaging (Thyroid, etc.)
      • Vascular imaging

      Quantity Information

      The visuals show 1 main ultrasound console (including monitor) and 2 ultrasound probes (1 GE 10L, 1 GE 3.5C). Additionally, integrated cables are present in the system.

      General Condition

      The device is a used, second-hand product. While the general structure of the device appears robust, there is age-related yellowing on the plastic components. This is a natural consequence of the device’s age, considering its manufacturing technology (CRT monitor, etc.). Its cosmetic integrity has been preserved.

      Physical Deformation and Wear

      • Plastic Casing: Typical “ABS plastic yellowing” due to sunlight or environmental conditions has been observed on the device’s white/cream-colored plastic casing, especially around the monitor and side panels. No breaks, deep cracks, or fragmentation are visible.
      • Control Panel: The inscriptions on the keypad are legible. No excessive fading has been detected on frequently used buttons (Freeze, Mode keys, etc.). The trackball (cursor ball) is intact and in place.
      • Cables: No major damage such as crushing or outer sheath peeling has been observed on the probe cables in the visual. The color of the cables appears slightly less yellowed compared to the device’s casing.

      Mechanical Components

      The device is seen standing on its wheeled stand with no balance issues. The monitor’s connecting neck to the main body is robust. The probe holder slots are complete and capable of holding the probes.

      Electronic Components and Screen

      • Screen Type: The device features an older-technology CRT (Cathode Ray Tube) monitor, not an LCD. This is one of the most prominent features confirming the device’s older manufacturing year.
      • Screen Condition: The screen is off, so no comments can be made regarding pixel errors or image quality. However, no distinct scratches or cracks are visible on the glass surface.
      • Buttons and Sliders: All TGC (Time Gain Compensation) slider buttons are in place (none appear missing). The rotary encoders (knobs) are complete.

      Accessories and Connections

      In the visual, a “Sony” branded unit (likely a medical printer or disk recorder) is located on the device’s lower shelf. Probes are seen connected to the probe ports. The power cable and other peripheral connection cables are positioned at the back or side of the device.

      Battery Status

      This type of mobile ultrasound device typically operates with mains electricity (AC), but may include internal UPS batteries for short-term transportation. It is not possible to obtain definite information about the battery’s presence or health from the visual. No external battery is visible.

      Label Information

      Since there is no frame in the visuals showing the device’s back label, the Serial Number, Place of Manufacture, and Electrical Values (Volts/Amperes) cannot be read. However, the model names (GE 3.5C and GE 10L) are clearly visible on the probe labels. There are paper labels, later affixed and partially worn, next to the F8 key on the keyboard.

      Size and Compatibility

      The device is of standard ergonomic medical device dimensions suitable for use by adults while standing. It is suitable for use by positioning it next to a bed or table. The probes are compatible with adult and pediatric use (depending on the selected probe).

      Year of Manufacture

      No clear date label is visible on the device. However, considering the “LOGIQ 3 Expert” series, the CRT monitor technology used, and the floppy disk drive/CD drive design, this device is estimated to be technology from the early to mid-2000s (2002-2008 range).

      Existing Fault and Risk Analysis

      No active error message or physical breakage (screen crack, casing fragmentation) is visible in the visuals. However, the following should be noted under the “Existing Fault Risk” heading:

      • The device falls into the old technology (Vintage/Legacy) category. Loss of brightness in CRT monitors over time is a common occurrence.
      • The trackball mechanism may seize up over time due to dust (it appears clean externally in the visual).
      • The yellowing of the plastic components indicates that the material may have hardened and become brittle; care should be taken during transportation.
      • Although there is no visible cable sheath damage, the internal wires of the probe cables may have worn out due to long-term bending.

      Conclusion

      The examined GE LOGIQ 3 Expert is an ultrasound device that comes with two different probes, designed for radiological and obstetric examinations, appearing complete but technologically an older generation. Its physical condition can be classified as “Good” for its age. The inclusion of both probes (Linear and Convex) increases the value and applicability of the set.