Ready For Sale

Whatsapp »
SKU: MBTRORAJQU4

Secondhand GE Voluson E10 BT22 Ultrasound Machine

Price: USD$ 15.000,00Yaklaşık: 645.000,00 TL

, , , ,

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside of Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 08.09.2025

      GE Voluson E10 Ultrasound Device Analysis Report

      Overview and Device Description

      The device shown in the images is a wheeled and mobile ultrasound system used for medical diagnostic purposes. Upon inspection, it was clearly determined from the inscriptions on the control panel and body of the device that its brand is GE and its model is Voluson E10. This device is designed for high-resolution 2D, 3D, and 4D imaging, especially in the fields of women’s health, obstetrics, and gynecology. The overall design of the product and the brand-model indications on it suggest that the device is original.

      The product subject to this report consists of one GE Voluson E10 ultrasound main unit and an attached power cable. No ultrasound probe (transducer) or other additional accessories are present in the images.

      Physical Condition and Assessment

      The general condition of the device appears to be very good and well-maintained. Based on visual inspections, it is assessed that the device may be lightly used or refurbished. No significant deformations such as noticeable scratches, dents, cracks, or discoloration have been observed on its casing. The white plastic surfaces of the device are clean, and there are no signs of wear such as yellowing.

      Electronic and Mechanical Component Analysis

      The physical condition of the device’s mechanical and electronic components appears visually sound.

      • Screens: The device features a large main monitor and a smaller touch screen integrated into the control panel. Both screens are powered off, so no comments can be made regarding their functionality or any potential screen issues. However, no visible cracks or scratches are present on the screen surfaces.
      • Control Panel: All control elements, such as the keyboard, function keys, rotary knobs, and trackball, are complete and in good physical condition.
      • Probe Ports: There are four probe connection ports at the front bottom of the device, which appear to be illuminated. No breaks or damage have been observed in these ports.
      • Wheels: The wheels, which enable the device’s mobility, appear sturdy and capable of movement. The locking mechanisms are also in place.
      • Power Cable: The device’s power cable appears intact and is plugged into an outlet.

      Accessories and Additional Parts

      Aside from the main unit of the ultrasound device, no accessories are present in the image. Ultrasound probes (transducers), a printer, or other peripherals necessary for the device’s operation are not available.

      Technical Label Information

      Despite detailed examination of the images, no technical labels containing information such as serial number, lot number, reference (REF) code, or manufacturing date are clearly legible on the device. Therefore, specific identification details for the device cannot be provided within this report.

      Potential Risk Assessment

      Based on the available images, no alarming damage or wear has been observed on the device. The device, which appears to be in very good physical condition, shows no signs of rust, crushed cables, or broken parts that would suggest an immediate breakdown risk. The overall condition of the device indicates its potential for long-term and stable use.