Sold Out

Whatsapp »
SKU: MBUFP55ZN52

Secondhand Philips HD3 Ultrasound Machine

Price: USD$ 5.000,00Approx: 210.000,00 TL

, , , ,

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment Options

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. For additional information, review the "services" page.

    For payments you can choose bank transfer, credit card, Western Union or cryptocurrency options. For additional information, review the "payment options" page.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Rapor tarihi: 13.08.2025

    Philips HD3 Ultrasound Device Analysis Report

    Overview and Device Description

    The visuals show an ultrasound device integrated onto a wheeled stand, including a monitor, control panel, and probe. The brand of the device is Philips, as clearly seen on the screen frame and the startup screen. The model has been identified as HD3, as indicated on the startup screen. The overall design of the device, the quality of the logo, and the arrangement of its components give the impression that the product is original.

    This product is an ultrasonography system used for medical diagnostic imaging of internal organs and tissues. It is shown in the visuals with one ultrasound probe.

    Box Contents and Quantity Information

    According to the visual analysis, the identified parts are:

    • 1 Philips HD3 main unit and wheeled trolley
    • 1 ultrasound probe

    No other accessories or components (box, user manual, etc.) are visible in the visuals.

    General Condition and State

    The general condition of the device is assessed as used. Slight dirt, stains, and discoloration/yellowing due to use are present on the wheeled trolley and console. However, its overall condition is good for its age, and it does not show any signs of major damage. The device is seen working in one visual, with an image displayed on its screen, which suggests that its basic electronic components may be functional.

    Physical and Mechanical Assessment

    Upon detailed examination of the device’s casing and plastic components, no serious cracks, fractures, or dents were detected. Only superficial scratches and color changes due to use and time are present on the surface. The buttons on the control panel and the trackball appear physically intact and undamaged. The mechanical arm that allows the monitor to move and the wheels have a functional appearance. There is some dust and dirt accumulation on the wheels.

    Electronic Components and Screen Analysis

    The device’s startup screen displays “PHILIPS” and “HD3” along with “Version: 1.0” and “© Koninklijke Philips Electronics N.V. 2006” information. This indicates that the device’s software dates back to 2006. No error codes or warning messages are present on the screen, which suggests that the system starts up normally.

    Additional components are integrated into the device’s main console:

    • A Sony brand VIDEO GRAPHIC PRINTER UP-897MD model thermal printer.
    • An LG brand CD/DVD drive.

    Probe connection ports are visible next to the device, and one probe’s cable is connected to one of these ports.

    Accessories and Connections

    Only one ultrasound probe is seen connected to the device in the visuals. The probe’s head is wrapped with a protective bag. The probe’s cable is white and shows no significant crushing or damage. The device’s power cable is visible at the lower rear and has a standard input.

    Potential Risk Assessment

    The fact that the device’s software dates back to 2006 indicates that the hardware also belongs to this period. This reveals that the device is an older model compared to current technology. However, no obvious malfunction or serious damage (broken parts, burn marks, exposed cables) that would prevent the device from operating has been observed in the visuals. Aside from cosmetic yellowing and superficial wear that indicate its age, the device appears to be well-preserved and functional. This leaves a positive impression that it could be used for a long time with regular maintenance.