Ready For Sale

Whatsapp »
SKU: MB8RKH8RTOX

Secondhand De Götzen Image X Periapical Fixed X-Ray Device

Price: USD$ 875,00Yaklaşık: 37.625,00 TL

, , , ,

Ready For Sale

Don't Want To Buy At This Price?

    Bid


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Ask a Question

      Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


      * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

      Click once and wait.

      Payment

      No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

      There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

      For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

      Shipping

      Standard Shipping Conditions

      In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

      Buyer and Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer Outside of Turkiye, Seller in Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer in Turkiye, Seller Outside Turkiye

      • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
      • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

      Buyer and Seller Outside Turkiye

      • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
      • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

      Objective AI Report

      Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

      Report date: 02.10.2025

      de Götzen Image X Dental X-ray Device Analysis Report

      Overview and Product Description

      The product shown in the images is a dental X-ray (periapical X-ray) device of the de Götzen brand, model Image X System. The main components of the device, consisting of the head, control unit, and articulated arm, are seen in a disassembled state. This system, understood to be of Italian origin from the label information, is used in dentistry for intraoral imaging. Various fasteners (screws, washers, etc.) are also included in a bag with the product.

      Brand, Model, and Originality

      The manufacturer and model information on the device’s label is clearly legible. According to this information, the product’s brand is de Götzen, and its model is Image X System Type Image X. Details such as “Made in ITALY”, the “CE 0434” mark, serial numbers, and the Toshiba brand tube used, provide strong evidence that the product is original equipment. The manufacturing year is stated as June 2003 on the label.

      Physical Condition and Deformation

      The general condition of the device indicates heavy use and exposure to physical wear and tear. Key findings include:

      • General Wear: The device’s beige plastic casing shows visible yellowing and discoloration. This indicates aging due to prolonged use and environmental factors. Generally, dirt, stains, and scratches are present on the surfaces.
      • Broken Parts: One of the articulated arm sections of the device is broken open. Due to this break, the internal cable connections are exposed, which is the most prominent damage to the device.
      • Disassembled Structure: The product is completely disassembled, and its parts are separate from each other. Reassembling it may require technical knowledge and potentially additional parts.
      • Cables: Spiral (helical) cables between the control unit and other components are present but have a stretched and deformed appearance.

      Technical and Mechanical Component Analysis

      Based on visual evidence, the following details were identified during the technical examination:

      • Control Unit: A control panel with a power button, numeric keypad, and digital display is present. The protective mica layer of the panel has lifted at the edges and is worn.
      • Mechanical Arm: The articulated arm is in a disassembled state, and one section is broken. This break has completely compromised the mechanical integrity of the device.
      • Accessories: Apart from the main parts of the device, a bag containing various mounting screws, washers, and nuts is present. However, it is unclear whether all mounting parts are complete. Accessories such as an external power cable are not visible in the images.
      • Battery: There is no evidence of an internal or external battery in the device. The 220V indication in the label information suggests that the device operates directly from mains electricity.

      Label Information

      The information on the label located on the head part of the device is as follows:

      • Manufacturer: de Götzen s.r.l. OLGIATE OLONA (Varese) ITALY
      • Model: IMAGE X SYSTEM TYPE IMAGE X
      • Serial Number (SN): 7164
      • Tube Brand/Model: Tube TOSHIBA D-082B
      • Tube Serial Number (SN): 41218
      • Manufacturing Date: June 2003
      • Electrical Ratings: 70 kVp, 10 mA, 0.520 kVA, 220 V ~ ±10% 50-60 Hz, 4.2 A
      • Classification: Class I Type B

      Fault Detection and Potential Risks

      The clearest finding in the images is that the device is faulty and damaged. Existing faults, rather than potential risks, are prominent.

      • Existing Fault: The broken arm of the device and the exposed internal cables constitute the most serious and clear fault. This condition indicates that the device is unusable in its current state. Furthermore, the disassembled nature of the device also raises the possibility of missing parts.
      • Potential Risks: Even if the exposed cables are repaired, there is a possibility that the plastic components have become brittle due to the device being over 20 years old. This could lead to new breaks in the future. The stretching in the spiral cables may have caused breaks in the thin wires inside.

      Conclusion and Evaluation

      The provided images belong to parts of a de Götzen Image X model, 2003 manufactured dental X-ray device. The device is in a disassembled state, has serious physical damage (broken arm), and is notably aged. The label information is legible and details the product’s technical specifications. The current condition of the device clearly indicates that comprehensive repair and professional assembly will be required to make it operational. No documents or additional accessories are visible in the images.