Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 25.05.2026
Report code: 1779715881
GE Revolution Brivo CT385 Computed Tomography Scanner Analysis Report
Device Identification
The images belong to a professional Computed Tomography (CT) scanner system used for medical imaging purposes. The system consists of the main scanning unit (gantry), a section of the patient table, and an external power/control cabinet.
Brand and Model
The GE logo and the Revolution model series name are clearly visible on the gantry unit of the device. On the technical labels on the unit, the model information is specified more precisely as Brivo CT385. The GE Medical Systems inscription is also present on the external cabinet. Based on this data, the brand of the device is GE, and the model is Revolution Brivo CT385.
Authenticity
The quality of the logos on the device, the detailed structure of the technical labels, the Intertek ETL certification marks, and the overall industrial workmanship quality indicate that the product is an original GE Medical Systems product.
Usage Areas
This device is used to create detailed cross-sectional images of the body using X-rays. It is widely used in radiology departments for diagnosis and assessment in a wide variety of medical branches such as oncology, cardiology, neurology, orthopedics, and emergency medicine.
Quantity Information
The images show one complete CT scanner system (gantry and attached table section) and one external power/control cabinet.
General Condition
The outer casing of the device appears clean and well-maintained. In the image showing the internal mechanism, it is noted that the components are organized and there is no excessive contamination. The general condition of the device is good.
Physical Deformation
There are no noticeable deep scratches, cracks, or breaks on the white and gray plastic covers of the gantry unit. The metal chassis of the external cabinet also appears to be in good condition. The control panel and buttons are intact.
Mechanical Components
The rotating mechanism, belts, and motor structure inside the gantry appear to be intact. The headrest attachment of the patient table is in place. No mechanical issues were detected from external observation.
Electronic Components
Complex wiring, electronic boards, and components related to the X-ray tube are visible inside the gantry. Cable connections appear organized. The power and gantry activation indicator lights on the external cabinet are lit green, indicating that the system is receiving power.
Accessories
The images show a blue cover on the patient table, a headrest attachment, and some hand tools (Allen key set, etc.). The main accessories required for the operation of the device (console computer, etc.) are not present in the images.
Label Information
The following information has been identified from the labels on the device:
- Manufacturer: GE Hangwei Medical Systems Co., Ltd.
- Model: Brivo CT385
- REF Model No: 5402412
- Serial Number: 432897HM7 (on the gantry label), E6PS1600040 (on the Chinese label)
- Manufacturing Date: February 2016 (2016-02)
- Power Information: 3~200/220/240/380/400/420/440/460/480V, 50/60Hz
- Instantaneous Power: 40kVA
- Continuous Power: 15kVA
- Classification: Class I, IPX0
Display Analysis
The letters “SJ” and green status indicator bars are visible on the small digital screen on the gantry. This indicates the standby or ready state of the system. No error codes or warning messages are visible.
Year of Manufacture
The year of manufacture is clearly stated as 2016 (February) on the technical labels.
Existing Faults
There is no clear evidence in the images, such as a broken part, burn marks, or an error message on the screen, to suggest that the device is faulty.
Potential Fault Risk
No significant wear, rust, or damage to the cables was observed in the images. The physical condition of the device is good, which indicates that the risk of potential failure is low.