Ready For Sale

Whatsapp »
SKU: MBMENPGR14C

Secondhand Philips MX16 Computed Tomography

, , , ,

Medbidding Engineers Verify

Secure Payment System

Price: USD$ 45.000,00 Approx: 2.025.000,00 TL
Bid

Ready For Sale

Objective AI Report

Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

Report date: 25.05.2026
Report code: 1779714872

Philips Computed Tomography Device Analysis Report

Device Identification

The images show one Computed Tomography (CT) scanner system. The system consists of a main scanning unit (gantry) and a patient table.

Brand and Model

The Philips brand is clearly legible on the gantry unit of the device. However, there is no readable information regarding the specific model name of the device in the images. Therefore, the model information is not specified.

Authenticity

The quality of the logos on the device, the layout of the labels, the presentation of technical information, and the general workmanship details indicate that the product is original. The control panels on the gantry and the table mechanism are consistent with standard Philips designs.

Usage Areas

This device is an advanced diagnostic tool used for medical imaging purposes. It uses X-rays to create detailed, cross-sectional images of the body’s internal structures. It is used in radiology departments and many different branches such as oncology, cardiology, neurology, and emergency medicine for the diagnosis, treatment planning, and monitoring of diseases.

Quantity Information

There is one integrated CT scanner system (gantry and table) in the images. Additionally, a blue protective cover on the table and a headrest accessory in the gantry opening are visible.

General Condition

The general condition of the device appears clean and well-maintained. There are no visible signs of wear on the outer casings or the table surface. It is understood from the active digital displays on the control panels that the device is installed and operational.

Physical Deformation

No scratches, dents, cracks, discoloration, or dirt have been detected on the outer casing, patient table, or control panels of the device. The plastic components maintain their integrity.

Mechanical Components

Mechanical parts such as the rail system of the patient table, the gantry opening, and the grab handle on the table appear to be in good working order when viewed from the outside. No tears or sagging have been observed on the cushion on the table.

Electronic Components

The digital screens on the control panels located on both sides of the gantry are active, and numbers (e.g., ‘303’ and ‘528’ on the right panel) can be read on them. This indicates that the electronic systems of the device are at least partially powered and operational.

Accessories

A blue protective cover on the patient table and a patient headrest in the gantry opening are visible in the images. There is a yellow warning label on the table stating that the maximum load capacity is less than or equal to 200 kg. No other accessories or cable connections are visible from the outside.

Battery Status

No information regarding whether the device has an internal or external battery could be obtained from the images.

Label Information

There is a detailed technical label on an X-ray tube housing located inside the device. The information on this label is as follows:

  • Manufacturer: Philips Medical Systems DMC GmbH
  • Manufacturing Date: 2024-02
  • X-Ray Tube Housing Assembly Model: CTR2150CEPN
  • X-Ray Tube Housing Assembly REF: 9896-055-92424
  • X-Ray Tube Housing Assembly SN: 26891S198857
  • X-Ray Tube Model: DU 5008C
  • X-Ray Tube SN: 198857
  • Nominal X-ray Tube Voltage: 140 kV IEC 60613:2010
  • Focal Spot Information: 0.5×1.3 IEC 60336, 1.0×1.3 IEC 60336
  • Certifications: CE 0123, CSA

Additionally, software information is included in a screenshot:

  • Software Name: Mx Workspace
  • Version: V2.0
  • Date: 27-Feb-2018
  • Copyright: Koninklijke Philips Electronics N.V. 2003

Screen Analysis

The red digital displays on the right control panel on the gantry are active. The numbers ‘303’ are visible on the top display, and ‘528’ on the bottom one. These numbers are likely technical values related to table position or scanning parameters and do not contain any error messages. The displays on the left panel also appear active, but the numbers are not clearly legible.

Dimensions and Compatibility

The label on the patient table states that the table is suitable for patients weighing a maximum of 200 kg. The size of the gantry opening appears suitable for scanning standard adult patients.

Year of Manufacture

According to the label on the X-ray tube housing, the manufacturing date of this specific part is February 2024. This indicates that the device is a relatively new model or has recently undergone a significant part replacement.

Documents

No invoices, warranty certificates, or user manuals for the device are visible in the images.

Usage Duration

There is no information in the images (on screens or labels) regarding the total operating hours or the number of scans performed by the device.

Existing Faults

There is no clear evidence in the images, such as a broken part, a severed cable, or an error code on the screens, indicating that the device is faulty.

Potential Fault Risk

The examination of the images revealed no negative conditions such as severe wear, rust, or damage to the cables. The external condition of the device is quite good, and the fact that a critical component like the X-ray tube has a 2024 manufacturing date indicates that the system is current and well-maintained. Based on this data, it can be said that the device is in good condition and does not carry any visible risk of failure.