Sold Out

Whatsapp »
SKU: MB93U2RT43Z

Secondhand Konica Minolta Regius Sigma 2 CR Device

, , , ,

Price: USD$ 4.600,00 Approx: 207.000,00 TL

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    If there is a local operation center in the seller's country:

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operation center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    If there is no operation center in the seller's country:

    • Technical Inspection: Inspections are performed by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it directly to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 11.03.2026

    Konica Minolta REGIUS Sigma II CR Device Analysis Report

    Device Identification and Brand Model Information

    The main device in the image is a computed radiography (CR) cassette reader used in medical imaging systems. Upon examining the logo and texts on the front lower part of the device, its brand was identified as Konica Minolta, and its model as REGIUS Σ II (Sigma II). A radiography cassette bearing the inscription REGIUS is located in the device’s reading slot.

    Areas of Use

    This device is used to read digital image data from phosphor plate CR cassettes used in X-ray examinations, transfer them to a computer environment, and erase the cassette to prepare it for the next examination. It is suitable for use in radiology departments of hospitals, clinics, and medical centers.

    General Condition and Physical State

    The device’s outer casing is in white and light gray tones. No breaks, deep scratches, cracks, or dents that would impede use were observed on the casing. The device’s general condition is used but maintains its integrity. Horizontal ventilation grilles are located on the front lower panel. A black power switch (on/off button) is located in the lower left corner.

    Mechanical and Electronic Components

    To the left of the cassette input slot, there is a vertically arranged electronic indicator panel displaying the device’s status. On this panel, from top to bottom, there are Ready (Hazır), Busy (Meşgul), and Error (Hata) indicator lights, followed by a yellow Erase (Silme) button at the very bottom. There is no visible deformation in the mechanical tray and slot where the cassette is inserted.

    Workstation and Accessories

    The CR device is integrated with a computer workstation to process images and manage patient records. The workstation components shown in the image are as follows:

    • Computer Case: A black Lenovo ThinkCentre brand desktop computer case. The front panel of the case shows significant dust accumulation, stains, and physical signs of use.
    • Monitor: A black Lenovo brand LCD/LED monitor. A medical software with a patient record, search, and viewing interface is open on the screen. No physical damage or pixel errors were observed on the screen.
    • Peripherals: A standard black Q keyboard and a black computer mouse are connected to the system.

    Quantity Information

    The quantities of hardware identified in the image are listed below:

    • 1 unit Konica Minolta REGIUS Σ II CR Reader Device
    • 1 unit CR Imaging Cassette (on the device)
    • 1 unit Lenovo ThinkCentre Computer Case
    • 1 unit Lenovo Monitor
    • 1 unit Keyboard
    • 1 unit Mouse

    Potential Malfunction Risk

    No physical damage indicating a potential malfunction was observed on the outer surface or cassette slot of the Konica Minolta CR device. The device’s condition is generally good. However, the heavy dust accumulation on the front panel of the connected Lenovo computer case may indicate dust buildup in the internal hardware (fans and cooling blocks) of the case. Since this situation could lead to the computer overheating in the long term, routine cleaning and maintenance for the computer case are recommended.