Don't Want To Buy At This Price?
Sorry. This product has been sold. You cannot bid. Please check out other products.
Sold Out
Price: USD$ 4.600,00 Approx: 207.000,00 TL
Sold Out
Sorry. This product has been sold. You cannot bid. Please check out other products.
No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.
There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.
For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.
In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.
If there is a local operation center in the seller's country:
If there is no operation center in the seller's country:
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 11.03.2026
The main device in the image is a computed radiography (CR) cassette reader used in medical imaging systems. Upon examining the logo and texts on the front lower part of the device, its brand was identified as Konica Minolta, and its model as REGIUS Σ II (Sigma II). A radiography cassette bearing the inscription REGIUS is located in the device’s reading slot.
This device is used to read digital image data from phosphor plate CR cassettes used in X-ray examinations, transfer them to a computer environment, and erase the cassette to prepare it for the next examination. It is suitable for use in radiology departments of hospitals, clinics, and medical centers.
The device’s outer casing is in white and light gray tones. No breaks, deep scratches, cracks, or dents that would impede use were observed on the casing. The device’s general condition is used but maintains its integrity. Horizontal ventilation grilles are located on the front lower panel. A black power switch (on/off button) is located in the lower left corner.
To the left of the cassette input slot, there is a vertically arranged electronic indicator panel displaying the device’s status. On this panel, from top to bottom, there are Ready (Hazır), Busy (Meşgul), and Error (Hata) indicator lights, followed by a yellow Erase (Silme) button at the very bottom. There is no visible deformation in the mechanical tray and slot where the cassette is inserted.
The CR device is integrated with a computer workstation to process images and manage patient records. The workstation components shown in the image are as follows:
The quantities of hardware identified in the image are listed below:
No physical damage indicating a potential malfunction was observed on the outer surface or cassette slot of the Konica Minolta CR device. The device’s condition is generally good. However, the heavy dust accumulation on the front panel of the connected Lenovo computer case may indicate dust buildup in the internal hardware (fans and cooling blocks) of the case. Since this situation could lead to the computer overheating in the long term, routine cleaning and maintenance for the computer case are recommended.