Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 14.02.2026
ERBE ICC 300 Electrosurgical Unit Analysis Report
Device Identification
The device shown in the image is an electrocautery (electrosurgical) unit used in medical procedures to perform surgical cutting and coagulation processes. The device has a horizontal form factor suitable for desktop use and features various control modules and digital displays on its front panel.
Brand and Model Information
The brand and model information is clearly and legibly located in the upper left corner of the device’s front surface:
- Brand: ERBE
- Model: ICC 300
This information has been definitively identified from the typography on the device. No other brand or model indications are present.
Authenticity
The logo placement on the device’s front panel, the fonts used, the quality of the control buttons, the arrangement of color-coded panels (Yellow-Cut, Blue-Coagulation), and the industrial craftsmanship details indicate that the product is an original ERBE manufacture. The neatness of the labels and the panel structure do not give the impression of a counterfeit or imitation product.
Areas of Use
The ERBE ICC 300 is designed for tissue cutting (Cut) and bleeding control (Coagulation) during surgical interventions. It is used for tissue manipulation in specialties such as general surgery, orthopedics, urology, gynecology, and gastroenterology. It is understood from the separated sections on the panel that it has Monopolar and Bipolar operating modes.
Technical Specifications and Panel Analysis
The device’s front panel is logically divided into sections according to its functionality:
Left Panel (Indicators and Warnings):
- “FEHLDOSIERUNG / OUTPUT ERROR” and “EINSCHALTDAUER / TIME LIMIT” warning LEDs are present.
- A “RESET” button (in the form of a small hole) or indicator is located at the bottom.
Yellow Panel (AUTO CUT – Cutting Mode):
- This section is dedicated to the cutting (Cut) procedure.
- It features a 3-digit digital display area (dark) showing the maximum power value (MAX WATT).
- LED indicators are present to show the Effect level (sequenced as 1, 2, 3, 4).
- Up/down arrow buttons for power adjustment and symbolic buttons for mode selection (such as HIGH CUT) are available.
Blue Middle Panel (AUTO COAG – Coagulation Mode):
- This section is dedicated to the coagulation procedure.
- It offers three different coagulation mode options: “SPRAY”, “FORCED”, and “SOFT”, which are indicated by LED lights.
- It has its own independent digital display and directional buttons for power adjustment.
- A foot pedal or handpiece selection switch symbol (finger/pedal) is located in the lower right section.
Blue Right Panel (AUTO BIPOLAR):
- This section is dedicated to bipolar surgical procedures.
- It features 0, 1, 2, and “AUS/SET” options under the “AUTO START” function.
- This section also has its own power adjustment buttons and digital display panel.
Connection Points (Sockets)
Connection inputs are arranged on a black strip at the very bottom of the device. From left to right:
- Power Switch: Green, illuminated On/Off switch (currently appears to be in ‘I’ position, but the device is off).
- Neutral Electrode Input: A dual-pin input labeled “NEUTRAL”, used for patient plate connection.
- Monopolar Outputs: Two handpiece (pencil) inputs are available under the “CUT / COAG” label.
- Bipolar Output: On the far right, a wide socket input likely designed for bipolar forceps use.
Quantity Information
Only 1 unit of the ERBE ICC 300 electrosurgical main unit is present in the image.
Accessories and Missing Parts
Peripheral units and accessories necessary for the device’s operation are not present in the analyzed image:
- There is no electrical power cable.
- Monopolar cautery pencils are not present.
- The neutral electrode (patient plate) and its cable are missing.
- Bipolar forceps or cables are not present.
- Foot pedals (footswitch) are not available.
General Condition and Physical Deformity
The device is in good and clean cosmetic condition. Although it is a used product, the following details are noticeable:
- Casing: No significant dents, breaks, or cracks were observed on the metal body and plastic front panel. Corners and edges are intact.
- Surface: The text and numbers on the front panel are not erased and are clearly legible. No significant yellowing or discoloration is visible on the surface.
- Keypad: The surface of the membrane buttons is clean; no tearing or punctures due to excessive use are observed.
- Sockets: The black connection blocks at the bottom appear sturdy; no physical breakage has been detected.
Electronic Components and Battery Status
Since the device is not connected to electricity, its digital displays and LED indicators are off. Therefore, pixel loss, screen malfunction, or electronic functionality (heating, operating performance) cannot be tested visually. The status of external or internal batteries cannot be determined from the image; such devices typically operate directly from mains electricity.
Potential Fault Risk
Visual inspection revealed no traces of rust, oxidation, or liquid contact on the device’s outer casing. Its physical integrity is complete. However, it should be considered that the device is an “old model” medical equipment and its operational life depends on internal electronic components (capacitors, power boards, etc.). Visually, it does not pose a critical risk (e.g., broken port, detached button).