Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 17.07.2025
JSB-1200 Infusion Pump Analysis Report
Device Description and Intended Use
The device shown in the images is an infusion pump. Such devices are used in the medical field to administer fluids, medications, or nutrient solutions to patients intravenously in a controlled manner at a specific rate and volume. The drip sensor on the device ensures the accuracy of the procedure by monitoring the fluid flow rate. Thanks to its portable design and the mounting apparatus on its back, it can be easily attached to IV poles.
Brand and Model Information
The brand and model of the device in the images have been clearly identified.
- Brand: JSB
- Model: 1200
General Condition and Physical Assessment
The device is a used product. Its overall condition is at a level that can be considered normal for a medical device. There is some yellowing on its white plastic casing, which typically occurs over time. Minor scratches and slight abrasions, resulting from use, are observed on the device’s surface and corners. However, there are no cracks, fractures, or serious deformations on the casing. The labels on the front panel and the text on the buttons are legible.
Mechanical Components and Accessories
The mechanical parts and accessories of the device have been visually inspected.
- Quantity Information: The images show 1 unit of the JSB-1200 infusion pump and 1 drip sensor attached to the device.
- Pump Door: The front door where the IV set is placed and its mechanism appear to be solid. No issues were observed with the opening and closing of the door.
- Buttons: The buttons on the front panel, labeled “POWER”, “ALARM”, “PRIME/BOLUS”, “Mode”, “SWITCH”, “SELECT/CONFIRM”, “KVO”, “START/STOP”, and the directional keys are physically intact and in place.
- Mounting Clamp: On the back of the device, there is a metal clamp and a tightening screw used for securing it to an IV pole. This part appears to be functional.
- Accessories: A green drip sensor connected to the device with a coiled cable is present. There is no visible break or damage on the cable and sensor. No external power cord or other accessories are included in the images.
Technical Information and Labels
There is important information on the labels on the device. One of these labels contains calibration details.
- Brand Label: Infusion Pump JSB-1200
- Instruction Label: On the front face of the device, there is an instruction label explaining how to use the door mechanism.
- Calibration Label: There is a label affixed by AYMET BIOMEDICAL CALIBRATION CENTER. According to this label:
- Date of Service: 09/2023
- Expiration Date: 09/2024
A label showing the device’s serial number, REF code, or lot number is not clearly legible in the images.
Screen Analysis and Operational Status
The device’s screen is operational and has a blue backlight. Upon examining the screen images, the following information is legible:
- Status Message: A “ZAMAN DOLDU” (TIME’S UP) warning is clearly visible on the screen. This indicates that the set infusion time has been completed or signifies an alarm condition.
- Operating Mode: “ORAN MOD” (RATE MODE) is selected.
- Set Values: “ORAN d/dak” (Rate drops/min) is set to 1, “HED. HAC.” (Target Volume) is set to 0 ml, and “IV SET” is set to 5.0d/ml.
- Alarm Light: In conjunction with the “ZAMAN DOLDU” (TIME’S UP) message on the screen, the red “ALARM” light on the panel is illuminated. This is a normal function indicating that the current situation requires user intervention and does not signify a malfunction.
- Battery Status: At the bottom of the screen, there is an icon indicating the charge level of the device’s internal battery, and it appears that the battery is partially charged.
Potential Risk Assessment
Based on visual inspection, the device is in working condition and does not show any signs of fractures or obvious malfunctions. However, there are a few points to consider. The yellowing on the device’s casing indicates prolonged use or its age. The most significant finding is the calibration label on the device. According to this label, the device’s calibration validity expired in September 2024. In medical devices, calibration is critical for the accuracy of measurements. Therefore, the device may need to be recalibrated to be used safely and accurately. This is an assessment based solely on visual evidence and does not indicate a current malfunction.