Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 16.07.2025
Hoffrichter Carat I Ventilator Device Analysis Report
Overview and Product Description
The images show a ventilator device used to provide respiratory support. The brand and model of the device are clearly indicated as Hoffrichter Carat I on its front panel and rear label. The quality of the logo, the labels, and the overall workmanship give the impression that it is an original device. This device is a medical product designed to support lung functions.
Only 1 unit of the ventilator device is present in the images. Accessories necessary for the device’s operation, such as the power cable and patient hose sets, are not present in the images.
Use and Function
The device is a “Lung Ventilator.” Such devices are used to provide artificial respiratory support to patients who cannot breathe adequately on their own. It may be suitable for use in home or clinical settings. The mode options on the device’s front panel (PCV, PSV, SIMV, VCV) indicate that it can operate in different respiratory therapy modes.
General State and Condition
The device appears to be in generally good condition and well-maintained. It is understood to be a used product from some minor scratches and marks on it. However, it has a generally clean appearance and does not contain any major damage or dirt.
Physical Deformation and Mechanical Parts
Upon detailed inspection of the device’s casing, no serious physical deformation has been detected.
- Casing: The device’s gray and blue plastic casing has minor scratches and scuff marks due to use, especially on the edges and corners. There is no significant deformation on the white panel on the front face of the device.
- Mechanical Parts: The carrying handle, the control knob (rotary knob) on the front panel, and the menu and mode buttons appear to be intact and in place. The black rubber feet underneath the device are present and functional.
- Inlets and Outlets: The main respiratory circuit outlet, oxygen inlet port, and other connection points on the front panel appear visually sound. No breaks or damage have been observed on the power input and other sockets on the rear panel.
Screen Analysis and Operational Status
The device’s screen is in working condition, and no cracks or pixel errors are visible. The screen’s backlight is active, and the information on it is clearly legible. The data on the screen includes the following:
- Respiratory Parameters: Set treatment values such as IPAP (20.0 kPa), PEEP (5.0 kPa), Frequency (22 bpm), and IE (1:1.5) are displayed.
- Modes and Settings: Various settings such as Ramp, Inspir. Trigger, and Trigger Lock are shown in the “OFF” position.
- Status Icons: There are icons on the front panel and the screen indicating the power status and battery level. In the image, the battery icons show that the battery is full.
- Date and Time: The date “13.05.2022” and the time “14:35” are visible in the bottom right corner of the screen. This may indicate the last time the device was used or configured.
Label Information and Technical Details
The label on the rear panel of the device contains important technical information. This information is listed below:
- Product Type: Lung Ventilator
- Model Type: Type 9LV102
- Serial Number (SN): The space designated for the serial number on the label cannot be read as it is either blank or covered in the image.
- Place of Manufacture: Made in Germany
- Power Requirement: USE ONLY WITH POWER SUPPLY PCM 120 PS24 or SNP-A129-M!
- DC Input: DC INPUT 24 V — 5 A
- Oxygen Input: O₂ INPUT max. 15 l/min 1000hPa
- Certification: It has the CE 0123 mark.
Additionally, there is another barcoded label with “CARAT I” written on it on the upper rear part of the device.
Potential Risk Assessment
Based on visual inspection, no obvious malfunction or critical damage (broken parts, burn marks, crushed cables) that would directly prevent the device from operating has been detected. The minor scratches and signs of use on the device’s casing are cosmetic imperfections that should not affect its functionality. The overall condition of the device is good. However, this report is based solely on a visual analysis and is not a guarantee that all of the device’s functions are fully operational. In particular, missing accessories such as the power supply and patient hoses need to be procured.