Secondhand Hoffrichter Carat I Home Mechanical Ventilator
Price: USD$ 1.200,00Approx: 50.400,00 TL
Ready For Sale
Ask a Question
Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 23.07.2025
Hoffrichter Carat Series Respiratory Device Analysis Report
Overview and Device Identification
The product shown in the image is a home-use mechanical ventilator device designed to provide respiratory support. The overall design, control panel, and connection points of the device confirm that it is a medical respiratory device. The product is structured for either invasive (e.g., via tracheostomy) or non-invasive (with a mask) ventilation. The device in the image appears to be resting on a table or a flat surface. Objects in the background that are not directly related to the product have been excluded from the analysis.
Brand and Model
The brand of the device in the image is Hoffrichter, which is clearly visible on the front panel. Based on the “S|M|A|R|T FUNCTION” text and the overall design, the model is estimated to be from Hoffrichter’s Carat series. Internet research indicates that this design bears a resemblance to models like the “Carat II Pro”. There is a label on the device that reads “SKYMED MEDİKAL”; however, this is a technical service or distributor label, not a manufacturer’s label.
Physical Condition and Deformation Analysis
The device appears to be in a generally good and clean condition. It gives the impression of a lightly used or well-maintained product. Its physical condition can be summarized as follows:
- Casing: No cracks, breaks, dents, or significant color fading were observed on the device’s white and black plastic casing. The surface is clean and well-maintained.
- Screen: As the device is turned off, the operational status of the screen cannot be tested. Apart from slight fingerprints or smudges, there are no scratches or cracks on the screen’s surface.
- Buttons and Control Panel: The power, alarm silence, and other function buttons, as well as the rotary control knob, are physically intact and in place. The icons on them are not worn off and are clearly legible.
Accessories and Connection Ports
The following accessories and connection ports have been identified with the device in the image:
- Breathing Circuit: A transparent, flexible breathing circuit (hose) is seen connected to the device. The hose has a thin green line on it, which is likely used for pressure measurement. There are no visible tears or deformations on the hose.
- Connection Ports: On the front face of the device, there is a main outlet port where the breathing circuit is attached, and next to it, a port for supplementary oxygen (O2) input.
- Missing Accessories: Other standard accessories such as the power cable, user manual, or carrying case are not present in the image.
Label and Technical Information
There is no manufacturer’s label on the front of the device containing a model or serial number. Such information is usually located on the bottom or back of the device, and these parts are not visible in the image. The “SKYMED MEDİKAL” label on the top of the device belongs to a service provider and does not contain technical specifications of the product.
Potential Risk Assessment
Based on visual inspection, no severe deformation, corrosion, crushed cables, or broken parts that would suggest an immediate risk of malfunction have been observed. The overall condition of the device is very good. However, accessories such as the breathing circuit are consumables, may have a limited lifespan, and may need to be replaced regularly. This assessment is a forecast based solely on visual evidence, and it is important to state that the device’s full functionality must be verified by a technical service. As it stands, the device appears to be in a well-maintained condition rather than posing a potential risk of failure.