Sold Out

Whatsapp »
SKU: MBP6CS8HSY7

Secondhand GE Logiq 200 Pro Ultrasound Machine

Price: USD$ 2.250,00 Approx: 99.000,00 TL

, , , ,

Sold Out

Don't Want To Buy At This Price?

Sorry. This product has been sold. You cannot bid. Please check out other products.

Ask a Question

    Fill in the form below to send us your message. Click the button and wait. We will contact you as soon as possible.


    * We kindly ask you to write your Whatsapp number with the country code so that we can contact you quickly.

    Click once and wait.

    Payment

    No additional fees, full assurance. We provide complete financial and operational security in secondhand medical device trading. For this, we offer the "Secure Payment" service. This free service protects the rights of both parties by securing the buyer's money and the seller's product. The Secure Payment system is a standard assurance mechanism offered by Medbidding. For additional information, review the "services" page.

    There is no cash on delivery order system on the Medbidding platform. For payments to be made by credit card, the product to be purchased must comply with this payment method. You can contact us to get information about this. We would be happy to assist you.

    For payments made outside of Turkiye, you can choose bank transfer, credit card, Western Union or cryptocurrency options. Installment options are not currently available for credit cards other than Turkish banks.

    Shipping

    Standard Shipping Conditions

    In order to ensure secure transactions on Medbidding, the shipping process is managed through four different scenarios depending on the location of the buyer and seller. Free shipping is available for some categories. The terms below apply to all categories unless otherwise stated.

    Buyer and Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer Outside of Turkiye, Seller in Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer in Turkiye, Seller Outside Turkiye

    • Seller → Medbidding: The seller packages the product and sends it to the Medbidding operations center. The seller is responsible for this shipping cost.
    • Medbidding → Buyer: The product, inspected by Medbidding engineers, is sent to the buyer's address. The buyer is responsible for this shipping cost.

    Buyer and Seller Outside Turkiye

    • Technical Inspection: Technical inspections are performed by our business partner in the seller's country (where available) or by our engineers via remote video call.
    • Seller → Buyer: The seller packages the product and sends it to the buyer's address. The seller is responsible for this shipping cost.

    Objective AI Report

    Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.

    Report date: 23.11.2025

    GE LOGIQ 200 PRO Series Ultrasound Device Analysis Report

    Device Identification and Product Description

    The product examined in the images is a CRT monitor-equipped ultrasonography system, used for medical imaging, mounted on a wheeled mobile stand. The device consists of a main unit, a monitor, a control panel (console), and ultrasound probes integrated into the system.

    Brand and Model Information

    During the detailed examination, the device’s brand and model information was unequivocally identified as follows:

    • Brand: GE (General Electric)
    • Model: LOGIQ 200 PRO Series

    This information is clearly visible on the original brand label located on the top left frame of the monitor, in the system information displayed in the top right corner of the monitor’s startup screen, and on the side panel graphics. The phrase “LOGIQ 200” is prominent.

    Areas of Use and Purpose

    This device is used in healthcare institutions for imaging patients’ internal organs, vascular structures, or for pregnancy monitoring using ultrasound waves. It is a medical device used in diagnostic processes.

    Quantity Information

    A total of:

    • 1 Ultrasound Main Device (Console, Monitor, and Carrying Case)
    • 2 Ultrasound Probes (Transducers) are present in the images.

    General Condition and Originality

    The product is an original device belonging to the manufacturer GE. Its general appearance indicates a “used” condition. There are physical signs of aging that indicate the device’s age. The screen being operational suggests that the device is still electronically active. However, cosmetically, it bears heavy signs of use.

    Physical Deformation and Cosmetic Condition

    Significant deformations due to age and use have been observed on the device’s outer casing and control elements:

    • Yellowing: Intense discoloration (yellowing) is present on the control panel buttons, particularly in the QWERTY keyboard section, and on the plastic components of the casing. This indicates that the device is an older model and has been exposed to sunlight or the environment for a long time.
    • Trackball (Cursor Ball): Obvious signs of use and dirt are present on the trackball (cursor ball) in the center of the control panel.
    • Sliders (TGC Buttons): The bottommost of the TGC (Time Gain Compensation) slider buttons on the left is blue, while the others are beige. The arrangement of the sliders is complete; no missing caps are observed.
    • Probe Holders and Cable Channels: Dust and dirt accumulation due to use are present in the gel reservoir and probe holders on the right side.

    Screen Analysis and Operating Status

    The device’s CRT monitor is active and operational. The data on the screen is as follows:

    • Display: An active ultrasound scan window (in sector/fan form) is visible on the screen. Signal noise is present, but it is understood that the tube is displaying an image.
    • Date and Time: The date “10/03/22” and time “13:01:08” are visible in the upper right corner of the screen. This date indicates that the device was operational at least in March 2022 or that the system date was set this way.
    • Institution Information: The phrase “OZEL REMEDY HASTANESI” (Private Remedy Hospital) is located in the upper left corner. This proves that the device was previously registered in the inventory of a private hospital.
    • Technical Parameters: The depth (Depth) scale, gain (Map5), and other technical imaging parameters are readable on the left side.

    Probe and Accessory Analysis

    Two active probe connections have been made on the device, and the ports are full. The details of the probes are as follows:

    • Probe 1 (Linear Probe – 10L): The “10L” label is present on the connector. It is understood to be a 10 MHz linear probe typically used for superficial tissue and vascular imaging. The locking mechanism appears intact.
    • Probe 2 (Convex Probe – 3.5C): The “3.5C” label is present on the connector. It is a 3.5 MHz convex (curved) probe used for abdominal and obstetric imaging.
    • Probe Tip Condition: In close-up images, abrasions on the contact surfaces and small crack-like wear on the edges of the probe heads (lens/membrane parts) have been noticed. Particularly, a risk of deformation in the silicone/filling material at the joints of the probe surface is observed.

    Mechanical and Rear Panel Analysis

    Upon examining the rear part and mechanical structure of the device:

    • Dust accumulation is present in the ventilation grilles on the rear panel.
    • The warning label on the back of the monitor remains intact, but the fine print on it is unreadable due to the distance.
    • The handle is gray and appears sturdy.
    • Although the wheel structure and braking mechanisms are present in the image, their functional status cannot be confirmed from the visual.

    Label and Connector Information

    The specific technical labels and codes identified in the image are:

    • Port Label 1: “10L” (Linear probe input)
    • Port Label 2: “3.5C” (Convex probe input)
    • Lock Icons: Lock open/closed directional indicators are present on the connectors.

    Potential Failure Risk and Assessment

    Based on the data obtained from the images, the device’s electronic components (screen and processor) appear to be functioning at a basic level. However, the following aspects may pose potential risks:

    • Probe Lens Wear: The wear observed on the patient contact surfaces and edges of the probes may lead to artifacts (noise) in image quality or affect the gel permeability of the probe, potentially damaging the internal crystals. This situation needs careful inspection.
    • Obsolete Technology (CRT Screen): Given that the screen technology is CRT (cathode ray tube) and considering the device’s production period, the lifespan and brightness level of the display tube may have decreased over time.
    • Cosmetic Fatigue: Extensive yellowing and dirt on the button panels indicate that the device has been used for very long hours; this suggests a possibility of decreased button sensitivity.

    In conclusion, the GE LOGIQ 200 PRO Series system is a used medical device that, despite its age and visible wear, can power on, display an image on its screen, and has its probes attached, but is in need of maintenance.