Objective AI Report
Disclaimer: I am Medbidding AI. I am an unbiased AI robot. I have generated the following report automatically (without human intervention). The report was prepared by examining only the product images in the ad in detail. The report may contain errors. Medbidding and other parties disclaim any liability that may arise from this report or reliance on its contents. If you have any questions or notice an error in the report, please contact Medbidding engineers.
Report date: 06.05.2026
Report code: 1778076856
Covidien Somanetics INVOS 5100C Cerebral Somatic Oximeter Analysis Report
Device Identification
The device in the images is a Covidien Somanetics INVOS 5100C model cerebral and somatic oximeter. This device is used to monitor oxygen saturation in patients’ brain and body tissues using a non-invasive method.
Brand and Model
The brand of the device is Covidien, and the model is Somanetics INVOS 5100C. This information is clearly visible on the front panel, rear label, and the user manual.
Authenticity
The logos, labels, serial number, CE mark, and overall build quality on the device indicate that it is an original product. The label information is consistent.
Usage Areas
This device is used in branches such as anesthesiology, intensive care, cardiac surgery, and neurosurgery. By continuously monitoring patients’ cerebral (brain) and somatic (body) tissue oxygenation, it helps to detect potential risks of ischemia in advance.
Quantity Information
The images show 1 Covidien Somanetics INVOS 5100C device, 1 user manual, and various connection cables.
General Condition
The general condition of the device appears to be good. It is seen in protective plastic packaging in some images and without packaging in others. The device gives the impression of being clean and well-maintained.
Physical Deformation
No visible scratches, dents, cracks, or color fading have been detected on the device’s casing, screen, or buttons. The plastic components maintain their integrity.
Mechanical Components
There are no visible issues with the device’s mechanical parts, buttons, socket inputs, or carrying handle. The fan grille on the back is clean.
Electronic Components
The electronic components of the device appear intact when viewed from the outside. The socket inputs and pins are straight. There is no visual evidence (such as the screen being on) to confirm whether the device is in working order.
Accessories
The following accessories are visible with the device:
- 1 user manual (Operations Manual)
- Connection cables (socket ends appear intact)
There are various socket inputs on the device:
- 4 sockets for sensor connections on the front panel (numbered 1, 2, 3, 4)
- 2 serial ports on the rear panel (with 10101 symbol)
- 1 VGA output on the rear panel (with monitor symbol)
- 1 USB port on the side panel
- 2 sensor connection sockets on the side panel
There is no information in the images regarding the expiration date of the accessories.
Battery Status
The device has an internal battery. The rear label contains the information “Last Charge Date: 2017/05/30”. This indicates that the battery was last charged in 2017. No comment can be made about the current capacity or status of the battery from the image, but there may be a performance loss as it has not been charged for a long time.
Label Information
The following information is present on the rear label and the box label of the device:
- Serial Number: 17G10930X
- REF Code: 5100C-EU
- Manufacturing Date: 2017-06-09
- Power Information: 100-240 VAC ~, 50/60Hz, 1.0-0.5 Amps
- Fuse Information: T 2.5A/250V
- Manufacturer: Covidien llc, Mansfield, MA 02048 USA
- CE Mark: CE 0123
Screen Analysis
The device screen is off in the images. Therefore, no analysis could be made regarding the text, warnings, or menus on the screen.
Size and Compatibility
There is no specific information in the images regarding the size of the device or patient compatibility (infant/pediatric/adult). This information depends on the sensors.
Manufacturing Year
The manufacturing year of the device is 2017 (2017-06-09) according to the information on the rear label and the box label.
Documents
The device’s user manual (Operations Manual) is present in the images. No invoice or warranty certificate is visible.
Usage Duration
There is no information in the images regarding the operating hours of the device or how long it has been used.
Existing Fault
There is no clear evidence in the images that the device is faulty (broken parts, error messages, etc.).
Potential Fault Risk
The physical condition of the device appears good. No significant wear, rust, or crushing of the cables has been observed. The only potential risk is that the battery has not been charged for a long time (last charge date 2017). This situation may affect battery performance.













